smartctl 6.2 2013-07-26 r3841 [x86_64-linux-3.10.0-514.26.2.el7.x86_64] (local build) Copyright (C) 2002-13, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: Crucial_CT512MX100SSD1 Serial Number: 14340D0B24F1 LU WWN Device Id: 5 00a075 10d0b24f1 Firmware Version: MU01 User Capacity: 512,110,190,592 bytes [512 GB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: Solid State Device Device is: Not in smartctl database [for details use: -P showall] ATA Version is: ACS-2, ATA8-ACS T13/1699-D revision 6 SATA Version is: SATA 3.1, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Fri Sep 1 14:30:37 2017 EDT SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART overall-health self-assessment test result: PASSED General SMART Values: Offline data collection status: (0x80) Offline data collection activity was never started. Auto Offline Data Collection: Enabled. Self-test execution status: ( 248) Self-test routine in progress... 80% of test remaining. Total time to complete Offline data collection: ( 2380) seconds. Offline data collection capabilities: (0x7b) SMART execute Offline immediate. Auto Offline data collection on/off support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 2) minutes. Extended self-test routine recommended polling time: ( 6) minutes. Conveyance self-test routine recommended polling time: ( 3) minutes. SCT capabilities: (0x0035) SCT Status supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 16 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x002f 100 100 000 Pre-fail Always - 839010 5 Reallocated_Sector_Ct 0x0033 100 100 000 Pre-fail Always - 0 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 25514 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 13 171 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 0 172 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 0 173 Unknown_Attribute 0x0032 133 133 000 Old_age Always - 6718 174 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 11 180 Unused_Rsvd_Blk_Cnt_Tot 0x0033 000 000 000 Pre-fail Always - 4403 183 Runtime_Bad_Block 0x0032 100 100 000 Old_age Always - 0 184 End-to-End_Error 0x0032 100 100 000 Old_age Always - 0 187 Reported_Uncorrect 0x0032 100 100 000 Old_age Always - 3 194 Temperature_Celsius 0x0022 073 052 000 Old_age Always - 27 (Min/Max 19/48) 196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always - 0 197 Current_Pending_Sector 0x0032 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0030 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x0032 100 100 000 Old_age Always - 0 202 Unknown_SSD_Attribute 0x0031 133 133 000 Pre-fail Offline - 223 206 Unknown_SSD_Attribute 0x000e 100 100 000 Old_age Always - 0 210 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 0 246 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 70419612530 247 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 5353919392 248 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 165503670284 SMART Error Log Version: 1 Warning: ATA error count 0 inconsistent with error log pointer 3 ATA Error Count: 0 CR = Command Register [HEX] FR = Features Register [HEX] SC = Sector Count Register [HEX] SN = Sector Number Register [HEX] CL = Cylinder Low Register [HEX] CH = Cylinder High Register [HEX] DH = Device/Head Register [HEX] DC = Device Command Register [HEX] ER = Error register [HEX] ST = Status register [HEX] Powered_Up_Time is measured from power on, and printed as DDd+hh:mm:SS.sss where DD=days, hh=hours, mm=minutes, SS=sec, and sss=millisec. It "wraps" after 49.710 days. Error 0 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was in an unknown state. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 00 00 4b 40 Error: UNC at LBA = 0x004b0000 = 4915200 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 60 00 00 00 20 4b 40 08 28d+18:10:14.080 READ FPDMA QUEUED 60 00 00 00 1c 4b 40 08 28d+18:10:14.080 READ FPDMA QUEUED 60 00 00 00 18 4b 40 08 28d+18:10:14.080 READ FPDMA QUEUED 60 00 00 00 14 4b 40 08 28d+18:10:14.080 READ FPDMA QUEUED 60 00 00 00 10 4b 40 08 28d+18:10:14.080 READ FPDMA QUEUED Error -1 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was in an unknown state. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 00 00 4a 40 Error: UNC at LBA = 0x004a0000 = 4849664 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 60 00 00 00 4c 4a 40 08 28d+18:10:14.080 READ FPDMA QUEUED 60 00 00 00 48 4a 40 08 28d+18:10:14.080 READ FPDMA QUEUED 60 00 00 00 44 4a 40 08 28d+18:10:14.080 READ FPDMA QUEUED 60 00 00 00 40 4a 40 08 28d+18:10:14.080 READ FPDMA QUEUED 60 00 00 00 3c 4a 40 08 28d+18:10:14.080 READ FPDMA QUEUED Error -2 occurred at disk power-on lifetime: 0 hours (0 days + 0 hours) When the command that caused the error occurred, the device was in an unknown state. After command completion occurred, registers were: ER ST SC SN CL CH DH -- -- -- -- -- -- -- 40 51 00 00 73 48 40 Error: UNC at LBA = 0x00487300 = 4748032 Commands leading to the command that caused the error were: CR FR SC SN CL CH DH DC Powered_Up_Time Command/Feature_Name -- -- -- -- -- -- -- -- ---------------- -------------------- 60 00 00 00 a7 48 40 08 28d+18:09:14.080 READ FPDMA QUEUED 60 00 00 00 a3 48 40 08 28d+18:09:14.080 READ FPDMA QUEUED 60 00 00 00 9f 48 40 08 28d+18:09:14.080 READ FPDMA QUEUED 60 00 00 00 9b 48 40 08 28d+18:09:14.080 READ FPDMA QUEUED 60 00 00 00 97 48 40 08 28d+18:09:14.080 READ FPDMA QUEUED SMART Self-test log structure revision number 1 Num Test_Description Status Remaining LifeTime(hours) LBA_of_first_error # 1 Short offline Self-test routine in progress 90% 25512 - # 2 Short offline Aborted by host 00% 25394 - # 3 Vendor (0xff) Completed without error 00% 24282 - # 4 Vendor (0xff) Completed without error 00% 14468 - # 5 Vendor (0xff) Completed without error 00% 331 - # 6 Vendor (0xff) Completed without error 00% 304 - # 7 Vendor (0xff) Completed without error 00% 233 - # 8 Vendor (0xff) Completed without error 00% 162 - # 9 Vendor (0xff) Completed without error 00% 92 - #10 Vendor (0xff) Completed without error 00% 21 - SMART Selective self-test log data structure revision number 1 SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS 1 0 0 Not_testing 2 0 0 Not_testing 3 0 0 Not_testing 4 0 0 Not_testing 5 0 0 Not_testing Selective self-test flags (0x0): After scanning selected spans, do NOT read-scan remainder of disk. If Selective self-test is pending on power-up, resume after 0 minute delay.